For sales, service or support call your local distributor or: 1800-BUY-RIVET or
10 OIL MATERIAL SAFETY DATA SHEET (MSDS) Priming is ALWAYS necessary after the tool has been dismantled and prior to operating. It may also be nec
11 TROUBLESHOOTING Item numbers in parentheses refer to assembly drawing part numbers on page 9. Problem Possible Cause Remedy More than one op
12 Warranty Statement: Industrial Rivet & Fastener Co. Inc. (hereinafter “IRF”), hereby warrants to the initial retail customer or original aut
2 CONTENTS Features Page 3 Safety Page 3 Specifications Page 3 Air supply Page 4 Operation Page 4 Jaw C
3 SAFETY DO NOT USE OUTSIDE DEISNG INTENT OR WITH EQUIPMENT THAT IS NOT RECOMMENDED BY THE MANUFACTURER. ALWAYS DISCONNECT THE AIR SUPPLY BE
4 AIR SUPPLY The rivet tool is powered by compressed air at an optimum pressure of 85 psi. Do not exceed 90 PSI of air pressure. Explosion an
5 JAW CLEANING PROCEDURE / JAMMED GUN REMEDY 1. Disconnect tool from air supply 2. Leaving the nose piece attached, remove the nose case 3 using
6 MAINTENANCE IMPORTANT: DISCONNECT THE TOOL FROM THE AIR SUPPLY OR SWITCH OFF AT VALVE (54). REMOVE NOSE ASSEMBLY OR SWIVEL HEAD COMPONENTS. All
7 MAINTENANCE (CONTINUED) Valve Spool Assembly Maintenance Send into authorized repair center for service. Trigger Maintenance Procedure In
8 SCHEMATIC
9 SERVICE KITS & SPARE